Hy vfd manual May 27, 2017 · The manuals I have seen for this model have a different set of parameter definitions. 07=1 Dec 19, 2023 · HUANYANG (HYRIA) VFD Drive HY02D223B – 2. 0KW 220V Variable Frequency Drive Inverter VFD HY03D023B The HY Inverters HY03D023B is a high-quality Variable Frequency Drive (VFD) designed for precision motor control in industrial applications. They are the three terminals of an internal relay that can switch up to 3A at 30VDC or 250VAC. Parameters will "stick" (but only after hy_vfd. How to setup Chinese VFD to 2. I thought I would flip my 220v switch to energize the vfd, then power on my MASSO and be able to start/stop/control the spindle with the MASSO. 5KW HY01D511B This video covers a complete tutorial on programming an HY VFD along with correctly wiring it. Used in conjunction with the Mach 3 controller, it … Restoration and documentation of custom-built 4x4' CNC router at Twin Cities Maker hackerspace (aka the Hack Factory) in Minneapolis, MN. This is a HY 2. 2kW 20A 0. Jun 3, 2021 · Huanyang VDF Manual. 2kw spindle I noticed that there was a motor spinning sound coming from spindle but collet nut was not spinning. 5KW 2hp Variable Frequency Drive CNC Motor Inverter Converter for Spindle Speed Control HUANYANG HY-Series(1. 4. First I want to verify I have the base wiring done correctly. There is what is called the base frequency which is the motor nameplate base frequency, 60Hz in the US Download - SAKO Solar Inverter,Home Inverter,Lithium ion batteries,Solar panel,installation guide, catalogue, package download Sorry read and answered to quickly, that seems right although high. Dec 19, 2023 · HY Inverters High Quality 1. 0kW GT 11kW~18. May 15, 2021 · Recommended Huanyang Configuration Unlock VFD Config PD000 SET 0 SET – UNLOCK VFD CONFIG Initial Configuration provided HY for my 110V 2. According to the updated IEC 60204-1, a VFD’s spindle STOP command is considered as a valid Safe Torque Off (STO) that fulfils the stop category 0 requirement (so allows to e. 00 Hz (default was 50. 0 4. The HY Inverters HY01D523B is a top-of-the-line Variable Frequency Drive (VFD) designed for precision motor control in various industrial applications. HY HUANYANG VFD Converter,Variable Frequency Drive,Single Phase 110v Input/Output, (for Power ≤3HP Three-Phase Motor/Spindle) 0-400hz Speed Rotation (HY Series-110v 2. 5KW 2hp Variable Frequency Drive CNC Drive Inverter Converter for 3 Phase 110v Motor Speed Control Nov 4, 2017 · HY HUANYANG VFD Converter,Variable Frequency Drive,1 Phase to 3 Phase,220v Input/Ouput, for 3 Phase Motor/Spindle 0-400hz Speed Rotation (HY Series-220v 1. When all else fails, a factory reset will work wonders on the HY VFD. enable 1) and unload (unload hy_vfd) the driver at a halrun(1) prompt. Jun 27, 2010 · You signed in with another tab or window. Precautions include verifying Mar 8, 2022 · I’ve built my system with a 2. 1 Validity This manual describes the assembly, installation, commissioning and maintenance of the hybrid inverter. 5kW. The Huanyang inverter is normally supplied with an instruction manual. 00) PD002 SET 1 SET – DEFINE SOURCE OF HY Inverter; GT Inverter; 110v 110v to 220v 220v 220v to 380v 380v gt 7r5g 2 manual huanyang gt series manual huanyang vfd huanyang vfd manual huanyang vfd Nov 1, 2019 · I used the parameter set you have listed here and it worked first time. For example: Jan 22, 2024 · Some VFDs additionally have an emergency circuit support, like Omron MX2. Connections to the VFD are on R and T with S blank and ground to ground. , I don't recall having to set it either (that doesn't mean I didn't ). That said, the VFD can control the spindle ramp up and down speed within its amperage load limits. Yes there is a typo. 2kW HY Huanyang inverter fault manual CN Huanyang HY series inverter manual CN Huanyang Inverter SL Vector Manual CN Dec 19, 2023 · Huanyang VFD,single to 3 Phase,Variable Frequency Drive,2. I also have a HY 220 volt vfd with a 2. 2kw and have PD142 set to 9 amps than the spindle is drawing 10. Apr 16, 2018 · I have a HY VFD, not the same sires a yours but looks to be similar. See VFD manual. About Huanyang VFD We specialize in providing cutting-edge Variable Frequency Drives (VFDs) that ensure precise control and energy-efficient operation for your machinery and equipment. 2kW 3HP 220V input AC 10A for Motor Speed Control,HY Series huanyang hy02d223b vfd manual pdf Today we'll install the 2. 5kw 110v system set up with my 1F. (I dont own the product, just figured this would help EVERYone else Dec 19, 2023 · Huanyang (Hyria) VFD Drive HY01D511B – 1. I asked the hy seller on Amazon if they had an idea but no response yet. 5kW 2HP Model) - Amazon. Now i know , that must be set more seting, but reason why burned in 20 sec about 8000rpm ? To avoid problem on next spindle. PV modules). I have changed PB001 from 0 to 1 and now have spindle is on/off from Mach3 and the speed adjustment is from the VFD trim pot, manually. 2KW 220v 400hz spindle The spindle and VFD were running ok with a XHC MKX-V Mach3 Breakout Board and Mach3 but had issues with the stepper motors so i have reconfigured the CNC with a CSMIO IP-S and SIM CNC software and have now eliminated that issue but after re wiring the VFD to the new controller i Mar 30, 2015 · The Huanyang VFD and Hallmark motor were free to me so I will be using these for the first go. 2kw 400hz spindle. 2kw water spindle (Check your own manual) PD005 SET 400 SET – DEFINE MAX FREQUENCY SETTING TO: 400. Simple to use, just connect L1/L2 to any two of VFD input R/S/T. pdf - Free download as PDF File (. - jasonwebb/tc-maker-4x4-router For RS485. The inverter is capable of operating within a Dec 19, 2023 · Categories HY Inverter Tags 110v, huanyang inverter hy01d511b manual, hy01d511b manual, hy01d511b manual pdf, hy01d511b wiring, hy01d511b wiring diagram. -F, --max-frequency <n> (default: read from VFD) If specified, program register PD005 of the VFD with the specified max frequency of <n> Hz (and use the same max frequency in the hy_vfd driver). Please keep the VFD 110V Input 2. Power is single phase 220 wired directly off the 20 amp breaker while I wait for the recommended two pole switch. I have prorammed and wired several HY vfd`s over the years but now I was clever enough to buy a HY FC01 model for my Bridgeport. The issue I’m having is with the RS485 comm setup. PD176: 0: Inverter Frequency Standard. Please read carefully the operation manual before putting the inverter to use so as to correctly install and operate the inverter, give full play to its functions and ensure the safety. 5-400Hz HUANYANG ELECTRICAL HY03D023B download instruction manual pdf VFD 220V 3. 2KW, 110V The Huanyang (Hyria) VFD Drive HY02D211B is a powerful variable frequency drive designed to provide precise control over motors in various applications. Any ideas, is this a bad vfd…? VFD setup This manual assumes you have setup your VFD with valid register settings for your spindle and input power etc. ¶ GRBLHAL2000/Flexi-HAL specific hardware setup for 0-10V control 1 Notes on this manual 1. This document provides safety instructions and specifications for an HY series inverter. PD174 = 11. If for some reason you need a breaking resistor, you will need to look for another VFD. Connect the three wires of spindle to inverter s u v w terminal individually 1; Q water cooled spindle motor 1; Remote technical support can be provided to initial users 1; Skype china hy wechat china vfd e mail facebook service hy electrical com 1; Spindle motor 1 HUANYANG ELECTRICAL HY01D511B download instruction manual pdf VFD 110V Input 1. Jul 16, 2019 · The vfd will take that 2. com How to set-up the HY inverter. HUANYANG ELECTRICAL HY02D223B download instruction manual pdf VFD 220V 2. 5KW VSD 10HP 220V Variable Frequency Drive Inverter VFD Single To 3 Phase. g. There is no circuitry to support it. What I am doing now is looking at changing up to a 4. Information concerning the connected equipment is available from the manufacturer of the equipment. ⅠⅠⅠ. 5kW 2HP 110V Input for Motor Speed Control Categories HY Inverter Tags 110v, huanyang inverter hy01d511b manual Feb 28, 2024 · Model Input Power Output Power HY01D523B 1PH/3PH 220VAC±20% 50Hz/60Hz 3PH 0-220VAC 1. enable has been set true) so to set more than ten parameters it is possible to repeatedly load the driver with a set of registers to set then enable (setp hy_vfd. 2kW GT 4. 04=300 P0. Any Dec 14, 2010 · I have read few articles on Huanyang VFD. 2KW 3hp Variable Frequency Drive CNC VFD Motor Drive Inverter Converter for Spindle Motor Speed Control HUANYANG HY-Series(2. Please read carefully the operation manual before putting the inverter to use so as to correctly May 14, 2024 · 2 - Be able to turn the vfd on via wall switch and have the spindle stay still until it gets a command from the MASSO. But that is my guess as to what is happening. Jul 16, 2019 · The manual is calling for PD001 set to 0 PD002 set to 1 HY SERIES VFD AND BLACKBOX SET-UP OPTIONS #36 that-jim, Nov 10, 2021. I wanted to test as soon as possible since it will be couple of months before I complete my build. This VFD is ONLY applicable to three-phase 110V asynchronous motor Categories HY Inverter Tags 110v to 220v PD13= 08 is for Factory reset, Only use this to set VFD to Factory Default Settings PD014 Acceleration=12 ( Adjust to suit) PD015 Deceleration=12 (Adjust to suit) ( PD15 is ignored IF PD26=1 Then the Spindle will Coast to a Stop) PD141=220 ( Motor Rated Voltage ) (120 for VFD Rated for 120v ) PD142= ( Motor Max Amps) HY Inverters High Quality 1. It describes the various PD settings that can be applied. 0KW (or 3HP). After digging thru every HY VFD video on YT I did find one that fixed my problem. 1 - 10. 5Kw 7amp spindle. i. Note: 1. Install the inverter in a safe location, avoiding high temperature, direct sunlight, humid air or water. It’s 2. 5Kw spindle which would come with a HY5. 2KW 220V 10A AC Drive Frequency Converter Spindle Inverter VFD The HUANYANG (HYRIA) VFD Drive HY02D223B is a high-performance variable frequency drive designed for precise motor control in industrial applications. There have been numerous versions of the Huanyang VFD manuals posted on various forums over the last few years, most of them are incomplete in some respect ot other, so this page is an attempt to collect all the various versions together and hopefully make at least one full version This document provides instructions for the safe installation and operation of a HY series inverter. From what I understand VFDs take the incoming AC and rectify it to DC then "chop" it back up into the required AC phases, so I think the exact input frequency Huanyang VFD,Single to 3 Phase,Variable Frequency Drive,3kW 4HP 220V-230V Input/Output AC 13A for Motor/Spindle Speed Control,HY Series Visit the HY HUANYANG Store 4. 5kW GT 0. If you have a 2. You signed out in another tab or window. I am planning to buy a Huanyang VFD, but that last comment "it worked only for 45 days" puts doubts in proceeding with the purchase. While the manual indicates that it does, and even includes registers for setting it up. Main Circuit Wiring Schematic Diagram. 2KW 220v 400hz spindle The spindle and VFD were running ok with a XHC MKX-V Mach3 Breakout Board and Mach3 but had issues with the stepper motors so i have reconfigured the CNC with a CSMIO IP-S and SIM CNC software and have now eliminated that issue but after re wiring the VFD to the new This is a basic setup of a HUANYANG 5 hp VFD on a 3hp Bridgeport Style Milling machine running on single phase power. V. Windows can see the dongle, /dev/ sees it but all linuxcnc gives me is the "cannot open com port errno 22. I'm using a HY VFD 2. Any assistance is appreciated, here is the manual for the vfd I have. 5KW, 220V) Category: Tools & Home Improvement Dec 19, 2023 · Huanyang (Hyria) VFD Drive HY02D211B – 2. My manual says the input frequency 47-63 Hz. your max rpm may be different, consult your manual. 00=0 P0. 2KW spindle (I'll show others as well) Note: Due to product uPdates, the manual is subject to change without notice. See wiring diagram on page 12 of the HY VFD manual. It describes checks that should be performed upon delivery, the nameplate information, safety precautions before and during powering and operation, standards and specifications, installation instructions, wiring diagrams, operating instructions, and commissioning procedures. I did check out some of the threads you listed and they also helped. Dec 19, 2023 · HY01D511B‑T 1. I wouldn’t have thought it would make a big difference but, clearly, the VFD setup is different. link HY Inverter; GT Inverter; 110v 110v to 220v 220v 220v to 380v 380v gt 7r5g 2 manual huanyang gt series manual huanyang vfd huanyang vfd manual huanyang vfd HY Series Inverter – User Manual Edited by CNCDIY CNC Routing Machine System 3 I. 00 is maximum as set by pd005, the minimum should be 133 as set by pd011 (not recommended to be lower than this), note your VFD can display lower than 133, but the actual spindle will not go any lower than 133. If I am not satisfied with the performance I will upgrade to better equipment later. HY Spindle motor GT VFD HY 0. Increase value of PD014 and PD015 (repeat until tuned). The plugin reads set amps(PD142) than adds the out amps. Keep the inverter from the reach of children or persons not concerned. HY inverter 2,2kW Spindle watter cooling 2,2kW Then Configure the VFD PD001 = 1 (external terminal) PD002 = 3 (which was not in manual) PD044 = 1 (for RUN) PD045 = 5 (DIR. Aug 30, 2022 · I have a HY inverter Model 02D223B and a 2. Jun 11, 2016 · yes, see the dongle /dev/ ttyUSB0 None of this makes sense fresh stepconf, my vfd settings match the hy_vfd listed settings with the exception of baud rate PD164=1 for 9600 as written in the custom hal, however I changed PD164=2 and it made no dif. The inverter should keep away from the electromagnetic radiation source. The inverter should keep away from water and condensation. By default this output is set to switch when there is a fault. This manual does not cover any details concerning equipment connected to the unit ( e. 6 %âãÏÓ 1 0 obj >/OCGs[18 0 R 148 0 R 280 0 R 412 0 R 544 0 R 676 0 R 808 0 R 940 0 R 1072 0 R 1204 0 R 1336 0 R 1467 0 R 1596 0 R 1725 0 R 1854 0 R 1981 0 R 2094 0 R 2207 0 R 2320 0 R 2432 0 R 2544 0 R 2656 0 R 2768 0 R 2880 0 R 2992 0 R 3104 0 R 3216 0 R 3328 0 R 3440 0 R 3552 0 R 3664 0 R 3776 0 R 3888 0 R 4000 0 R 4112 0 R 4224 0 R]>>/Pages 3 0 R/Type/Catalog>> endobj 2 0 obj Page 1 Installation and Reference Manual SlideDriver ™ (X3) Hydraulic slide gate operator with Smart Touch Controller • www. So I have attached the manual I have for this model and a possible programming parameter file. 2KW, 220V) Online Store Huanyang Inverter - Free download as PDF File (. It is a variable frequency drive with a voltage rating of 220V and a power output of 3. Weird they said the 380v Fuling was unable to accept the higher input voltage. This is a closed loop between the motor and vfd just to test out function and learn more before incorporating the 1F. 0; voltage rating of the inverter, read-only. Register Value Description PD001 2 May 19, 2020 · I recently purchased a Huanyang CNC 7. 5KW 220V 7A Variable Frequency Drive Inverter VFD HY01D523B. The HY Inverter. 4 out of 5 stars 83 Jan 9, 2017 · Ok, Now your VFD has power. In my vfd instructions, setting pd0072 to 400 was like setting the max speed to 24000. " 2. 2KW HY02D223B Dec 19, 2023 · VFD,1 to 3 Phase,Variable Frequency Drive,1. 75kW~2. Note that the hy_vfd driver only supports RTU communication, not ASCII. May 1, 2022 · I have an 80mm spindle wc 1. With advanced features and reliable functionality, this inverter is well-suited for a wide range of machinery. 2KW HY02D211B May 10, 2024 December 19, 2023 by Hyria. Only the required register changes required for this PlugIn will be covered here. 4 amps. There's an area near the wiring that calls out poles for a braking resistor so I thought I'd check. 06=300 P2. 0KW 220V Variable Frequency Drive Inverter VFD The HY03D023B is a specific model of Huanyang inverter designed for CNC spindle motor speed control. 0KW 4hp Variable Frequency Drive CNC Motor Inverter Converter for Spindle Speed Control HUANYANG HY-Series(3. The following table summarizes the register settings required for this PlugIn. 5v and apply that percentage to the max spindle speed it knows, in this example 12000rpm. 2 KW Huanyang VFD and spindle instead of a router but I ended up purchasing GT series VFD instead of the HY series discussed in the YouTube videos I’ve found. 00 $252. Trying to get an inverter to accept 3ph input which here in NZ is 460v. 2kW manual MODEL: HY02D223B Technical Features: Input & Output Input Voltage: 220V, single phase or three phase Input Frequenc. 0KW 220V Variable Frequency Drive Inverter VFD HY04D023B. And also with the HY inverter. all necessary settings to make it run and what these settings actually do. With years of industry expertise, we are dedicated to powering your success. I have set up the vfd parameters to the best of my knowledge and many videos…lol I can press run and motor will spin up to 400Hz but the dial control on vfd does nothing for me. 5kW 7A 0. all settings have been verified to be correct. Wiring 1. The videos related to Huanyang VFDs (Variable Frequency Drives) cover operations and settings for different series, such as the GT series, P2 series, and FC01 series. It should say F400. 00) PD004 SET 400 SET – DEFINE BASE FREQUENCY SETTING TO: 400. 3) Factory reset the HY VFD a. This matches the default in the hy_vfd driver, change this if your setup has special needs. 0; rated current of the inverter, read-only PD175 = 0; inverter type = constant torque Mount the inverter on a metal or other noncombustible material to avoid the risk of fire. No reason for the VFD to be on when I'm not even in the shop. 2KW spindle. 5KW 380V AC drive vector control inverter frequency inverter spindle inverter VFD Huanyang (Hy) variable frequency drive inverters MODEL: GT-7R5G. You switched accounts on another tab or window. 5KW 220V 7A Variable Frequency Drive Inverter VFD HY01D523B The HY Inverters HY01D523B is a top-of-the-line Variable Frequency Drive (VFD) designed for precision motor control in various industrial applications. P0. I have been given this information from the seller. The issue is the remote wiring, I had on the former a fwd/rev sitch and two separate push buttons for start and stop as well as a pot for speed control. 2 WARNING %PDF-1. 2. HY01D523B-VFD-Manual. 0KW HY04D023B 220V 2. Single‑phase or 3‑phase 110V input, three‑phase 110v output, frequency 0‑50hz / 60hz, 0‑400hz. 0kW HY 5. I also cover the correct cable to use for VFD signal manipulat HY Series Inverter – User Manual Edited by CNCDIY CNC Routing Machine System 3 Ⅰ. com 800-321-9947; Page 3 Be sure to securely fasten all six limit ramps to the underside of the drive rail when installing a 50VF-series operator. 2kw VFD and Spindle. 2KW 220V AC drive spindle inverter frequency converter & Optional Parts (extension cable + box) Huangyang (Hy) VFD Driver VDF HY 0. This must match the device number you set on the Hyanyang VFD in register PD163. With the GT series VFD I’ve selected the comm Dec 19, 2023 · 1 x Single-Phase Inverter 1 x User Manual. It covers checks upon delivery, safety precautions before and during power-up and operation, standards and specifications, storage, installation, wiring, operation of the digital operator, commissioning, functions, maintenance, troubleshooting, optional devices, and user preferences. The HY Inverters HY04D023B is a robust and high-performance Variable Frequency Drive (VFD) designed for precise motor control in industrial applications. pdf) or view presentation slides online. 400. 2Kw and a 1. I have a HY inverter Model 02D223B and a 2. Scribd is the world's largest social reading and publishing site. Last edited: Nov 20, 2021. I am having a issue with the 0-10 volt signal not going below 5 volts. Basically, don’t trust me, I’m a random guy from the internet ! I guess the VFD came with the manual, but I Apr 11, 2021 · I received my HY VFD a couple of days ago. Power supply:Verify that the inverter's rated voltage coincides with the power supply Mini Specificatio n s: HY-M-A HY-MnB voltage to avoid a damage of the inverter. Set PD013 = 08 then reapply the register settings at the beginning of this document. the spindle works great from 15000(5volts)-24000(10volts) rpm, but I need it to turn at 7500 (0volts)rpm. 5-400Hz HY02D211B 3PH 110VAC±20% 50Hz±5Hz 3PH 0-110VAC 2. 0 out of 5 stars 208 ratings Dec 19, 2023 · HY Inverters High-Quality 3. $245. The VFD is 220v so I have the motor wired in the "Low Volt Can be used to set up to 10 registers. Model: Input Voltage 110v 110v to 220v 220v 220v to 380v 380v gt 7r5g 2 manual huanyang gt series manual huanyang vfd huanyang vfd manual huanyang Dec 19, 2023 · Categories HY Inverter Tags 110v, huanyang hy02d211b, hy02d211b manual, hy02d211b manual pdf, hy02d211b price, hy02d211b review, hy02d211b wiring diagram 110V 3KW HY03D011B 110V 1. 5 Spindle on my machine. 2KW 3hp Variable Frequency CNC Drive Inverter Converter for 3 Phase 110v Motor Speed Control Category: Tools & Home Improvement Group: Spindle Sanders All you have to know about Huanyang VFD. Reload to refresh your session. 2kw. I put one leg through a switch, so that the fan doesn't sit there running constantly. HY HUANYANG VFD Converter,Variable Frequency Drive,220VAC Single Phase Input to 220V Three Phase,for Motor/Spindle Speed Rotation (HY Series 220v 4kW-5HP Model) $164. 3. There is also other information available from other sources, but none of them are very clear in explaining how to actually change the settings, so hopefully this page will (default: 1) Set HYCOMM target (slave) number. Multi-Output 3 consists of the terminals marked FA/FB/FC. Inverter manual: Range 0 - 5, factory setting: 0 LinuxCNC: Set register PD165 (communication data method) to 3 (8n1 RTU). 5Kw inverter. Here are the VFD and motor labels. 7. I have come to conclusion that most of the problems with these VFD is either users not able to understand VFD configuration or plugging 380v 3 phase into a single phase 220v. Picture included, as well as PDF manual. This is an issue with the defined ramp up and ramp down time in the HY VFD registers. You might be interested in some of the content from these videos, such as multi-speed parameter settings, 485 communication, spindle motor driving, and more. so you end up with (2. FOR /REW) Other settings default. The inverter should keep away from direct sunlight, oil mist, steam and vibration environment. 0KW, 220V) Category: Tools & Home Improvement Feb 12, 2022 · Thanks for your input. Aug 28, 2021 · I'm hoping this thread is still viewed and someone can help. THE USE OF MANUAL---=-HY11D043B~HY30D043B. 02=300 p0. Please read carefully the operation manual before putting the inverter to use so as to correctly Jun 3, 2021 · The main circuit of the inverter can be broadly divided into two categories: voltage type is the inverter that converts the DC of the voltage source into AC, and the DC circuit filter is capacitor; current type is the inverter that converts the DC of the current source into AC, and its DC circuit filter is an inductor. Jul 25, 2019 · PD170 = 0; allows to add VFD temperature to the list of displayable values PD171 = 7; enables display of DC voltage, AC voltage, and PD170 (temperature) PD172 = 0; set to 1 to clear faults PD173 = 255. 5KW, 110V The Huanyang (Hyria) VFD Drive HY01D511B is a high-quality variable frequency drive designed for precise control of motors in various applications. The inverter can only be used at the places accredited by our company. a. 00 Add to Cart HY Inverter; GT Inverter; 110v 110v to 220v 220v 220v to 380v 380v gt 7r5g 2 manual huanyang gt series manual huanyang vfd huanyang vfd manual huanyang vfd Jan 17, 2023 · Hello out there. I am trying to set it up for the GDZ120X103-4. Introduction Thank you for purchasing and using the general-purpose inverter of HY series of multi-functions and high performance. While Testing with a 2. 2kW HY 4. HuanYang VFD Manual HY 0. Set up the VFD for RS485 control (PD001=2, PD002=2 for HY, check your model documentation for specifics), make sure that the controller can drive the VFD Debug issues with steps 2 and 3. May 6, 2019 · The VFD I have isn't the Hy, it's the YL620-A clone I guess. 98 Get it as soon as Sunday, Apr 6 When you turn on the VFD press the “»»shift” button. hysecurity. 5/10)*12000 = 4000rpm. Open navigation menu Join Date Jan 2005 Location USA Posts 15362 Downloads 0 Uploads 0 Apr 10, 2020 · Hi @Ddemnard, Disclaimer: I’ll provide some advice to hopefully steer you in the right direction, but staying safe and not damaging stuff is all on you 🙂 Don’t do any of the following blindly, you need to understand what it does and why, and double check everything I wrote. safely manually change the tool in this state). 2kW 3HP Model) 4. Please read carefully the operation manual before putting the inverter to use so as to correctly Dec 19, 2023 · Categories HY Inverter Tags 220v, huanyang inverter hy03d023b, huanyang vfd manual, hy03d023b datasheet, hy03d023b manual, hy03d023b manual pdf, hy03d023b wiring diagram 220V 4. Dec 19, 2023 · Categories HY Inverter Tags 110v to 220v, huanyang vfd manual, hy02d211b manual, hy02d211b t huanyang vf, hy02d211b t manual, hy02d211b t price, hy02d211b t review 110V 2. Contribute to RobertOlechowski/Huanyang_VFD development by creating an account on GitHub. The inverter should keep away from contaminative air such as corrosive gas, oil mist and conductive dust. HY HUANYANG HY01D523B download instruction manual pdf VFD 220V 1. Dec 19, 2023 · HY Inverters High Quality 4. I reset the vfd several times but problem persisted. HUANYANG Inverter Spindle Inverters Drive Frequency Converter Manual Wiring and Programming Thank you for purchasing and using the general-purpose inverter of HY series of multi-functions and high performance. 98 $ 164 . ) The settings. 03=300 P0. Step 2. This is a basic setup of a HUANYANG 5 h Oct 1, 2023 · – Source: Huanyang HY Series VFD Manual (PDF) For control by a Masso G3, which unfortunately lacks Modbus capability, this has to be controlled by the VFD’s programmable input terminals (like on diagram below), so these would have been set to “1” (external input terminals, here: digital terminal for run/stop, and analog 0-10 V terminal Use the digital common terminal (DCM) with outputs 1 and 2. I know what you mean about the manuals that come with the Chinese products. MANUAL HUANYANG INVERTER in this video i will try to explain as best i can how to program Chinese VFD. 00 (or another number) this is the frequency menu. I see also the HY inverter is a 380VAC 3P input +/-15. If you have no experience in driving a VFD, please refer to the instructions before operating the VFD. 2kw Spindle from RATTMMOTOR and the HuanYang VFD on my PrintNC00:00 - Intro00:10 - stuff you need00:27 - benchtesting01:04 - vfd ca 3. Now that our VFD has power, we need to go through and set all of the settings to the proper place for our 2. . Now to get the second relay switching 230v AC for the cutting fluid system. ggy btn eckgbu muec ipxfwt bqbltp lrtvhd kvlbe ocghb iqgssh ubjr ibsbefii pgj wzlhgh rtuxg